ZIMMERLIN

Pakninger til Trykdæksler ( o-ring)

Fødevare-/ Pharma udstyr

Her finder du et bredt udvalg af O-rings Pakninger til tankdæksler.

Kontakt os gerne for at høre mere om certifikater mv. 

  • Tilbehør til ZTD - ZTDA - ZTDIN - ZTDAV
  • Tilbehør til ZTO - ZTOF - ZTDO
  • Tilbehør til ZTG - ZTGM - ZTK
  • Silikone - VMQ - MVQ - EPDM - NBR
  • PTFE - FEP - PFA - FPM - FKM - Viton
O-ring Gasket press. Cover

O-ring Gasket press. Cover

EPDM O-ring 2019

EPDM O-ring 2019

EPDM P-Profil 2019

EPDM P-Profil 2019

FEP-EPDM O-ring 2019

FEP-EPDM O-ring 2019

FEP-VMQ O-ring 2019

FEP-VMQ O-ring 2019

FEP-FKM O-ring 2019

FEP-FKM O-ring 2019

PFA-VMQ O-ring 2019

PFA-VMQ O-ring 2019

VQM O-ring 2019

VQM O-ring 2019

P-Profil Pakning 2019

P-Profil Pakning 2019

FKM O-ring 2019

FKM O-ring 2019

Udvalgt variant

Udvalgt variant

Specifikationer

Beskrivelse O-ring Ø107 x 8 mm
Certifikater FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
Design Norm Vulkaniceret EPDM FDA
Materialekvalitet EPDM
Pressure range -1/+40 Bar
Temperaturområde -50°C / +150°C

Mål & tilslutninger

Tekniske illustrationer

EPDM O-ring 2019

EPDM O-ring 2019

OEM Pakningsoversigt til trykdæksler

O-ring Gasket press. Cover

O-ring Gasket press. Cover

Produktbeskrivelse

Her finder du et bredt udvalg af O-rings Pakninger til tankdæksler.

Kontakt os gerne for at høre mere om certifikater mv. 

Tilbehør

Accredia logo
Produktnyheder

Senseca Italy Calibration Center opdaterer akkrediteringsnummer og logo

Fra og med 2025 har ACCREDIA introduceret et nyt logo og ændret logikken for tildeling af akkrediteringsnumre til kalibreringslaboratorier. Som følge heraf er Sensecas akkrediteringsnummer nu 00171, hvilket erstatter det tidligere LAT 124.

Senseca har fuldført denne opdatering inden den officielle deadline den 30. september 2025, og vi er glade for at kunne informere om, at alle nødvendige tilpasninger er implementeret.

Tescom Trykregulatorer
Produktnyheder

TESCOM MULTI-PURPOSE TRYKREGULATORER

Vi tilbyder et bredt udvalg af Tescom trykregulatorer, der dækker alt fra laboratorieanalyser til industrielle gasinstallationer. Tescom er kendt for sin høje kvalitet, fleksibilitet og pålidelighed – uanset om du arbejder med brandfarlige gasser, kalibreringsudstyr eller trykpaneler.

Kabelgennemføring
Produktnyheder

ORGANISÉR DINE KABLER MED VORES KABELGENNEMFØRINGSSYSTEM FRA CONTA-CLIP 

Lær mere om, hvordan innovative kabelgennemføringssystemer kan imødekomme nutidens industrielle udfordringer ved at spare tid, forenkle installationen og tilbyde enestående fleksibilitet. Følg med, når vi dykker ned i, hvordan vores kabelgennemføringssystemer fra Conta-Clip påvirker industrielle installationer

VS pumpe listing image
Produktnyheder

NY VAKUUMPUMPE MED FOKUS PÅ DRIFTSSIKKERHED OG LAVERE VEDLIGEHOLDELSE

Industrien kræver driftssikre løsninger med minimal vedligeholdelse – og det er præcis, hvad den nye VS-serie fra Salvatore Robuschi leverer.
Når pålidelighed og effektivitet er afgørende, tilbyder VS-serien en gennemtænkt løsning inden for væskeringsvakuumpumper.

Lær mere om manometre_
Tips og guides

ALT DU BEHØVER AT VIDE OM MANOMETRE

Her har vi samlet omfattende information om manometre, til dig, der ønsker at fordybe dig og læse mere. Vi forklarer forskellen mellem de forskellige typer manometre, gennemgår almindelige begreber og giver dig værdifulde tips til, hvad du bør være opmærksom på både før og efter dit køb af et manometer. Længere nede på siden finder du også en skalaopdelingstabel og en omregningstabel for forskellige trykenheder.

Elektroniske sikringer Listing
Tips og guides

Derfor skal du bruge elektroniske sikringer

Switch-mode strømforsyninger og automatsikringer udgør grundlaget i et 24 V DC-system. En konsekvens af funktionen i disse produkter er, at det i mange tilfælde kan være svært at opnå selektive udløsningsbetingelser. Løsningen er elektroniske sikringer fra Lütze eller PULS.

Favoritter Artikler Beskrivelse Certifikater Design Norm Materialekvalitet Pressure range Temperaturområde Pris
O-ring Ø107 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
Vulkaniceret EPDM FDA
EPDM
-1/+40 Bar
-50°C / +150°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø107 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+40 Bar
-40°C / +140°C
O-ring Ø107 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+40 Bar
-60°C / +200°C
O-ring Ø107 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+40 Bar
-20°C / +200°C
O-ring Ø107 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+40 Bar
-60°C / +230°C
O-ring Ø107 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+40 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø107 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - ADI - Fri for phalater - DVDW
DIN ISO 7619-1
-1/+40 Bar
-20°C / +200°C
O-ring Ø1007 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
EPDM FDA USP VI
EPDM
-1/+10 Bar
-40°C / +140°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø1007 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+10 Bar
-40°C / +140°C
O-ring Ø1007 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+10 Bar
-60°C / +200°C
O-ring Ø1007 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+10 Bar
-20°C / +200°C
O-ring Ø1007 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+10 Bar
-60°C / +230°C
O-ring Ø1007 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+10 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø1007 x 8 mm
FDA 21 CFR 177.2600 - A3 - Fri for phalater
FKM ASTM D 2240
-1/+10 Bar
-20°C / +200°C
O-ring Ø157 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
Vulkaniceret EPDM FDA
EPDM
-40°C / +140°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø157 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+40 Bar
-40°C / +140°C
O-ring Ø157 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+40 Bar
-60°C / +200°C
O-ring Ø157 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+40 Bar
-20°C / +200°C
O-ring Ø157 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+40 Bar
-60°C / +230°C
O-ring Ø157 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+40 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø157 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - ADI - Fri for phalater - DVDW
DIN ISO 7619-1
-1/+40 Bar
-20°C / +200°C
O-ring Ø207 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
EPDM FDA USP VI
EPDM
-50°C / +150°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø227 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+40 Bar
-40°C / +140°C
O-ring Ø207 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+40 Bar
-60°C / +200°C
O-ring Ø207 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+40 Bar
-20°C / +200°C
O-ring Ø207 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+40 Bar
-60°C / +230°C
O-ring Ø207 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+40 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø207 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - ADI - Fri for phalater - DVDW
DIN ISO 7619-1
-1/+40 Bar
-20°C / +200°C
O-ring Ø257 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
Vulkaniceret EPDM FDA
EPDM
-50°C / +150°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø257 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+40 Bar
-40°C / +140°C
O-ring Ø257 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+40 Bar
-60°C / +200°C
O-ring Ø257 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+40 Bar
-20°C / +200°C
O-ring Ø257 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+40 Bar
-60°C / +230°C
O-ring Ø257 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+40 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø257 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - ADI - Fri for phalater - DVDW
DIN ISO 7619-1
-1/+40 Bar
-20°C / +200°C
O-ring Ø307 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
EPDM FDA / USP VI
EPDM
-1/+25 Bar
-50°C / +150°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø307 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+25 Bar
-40°C / +140°C
O-ring Ø307 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+25 Bar
-60°C / +200°C
O-ring Ø307 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+25 Bar
-20°C / +200°C
O-ring Ø307 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+25 Bar
-60°C / +230°C
O-ring Ø307 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+25 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø307 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - ADI - Fri for phalater - DVDW
DIN ISO 7619-1
-1/+25 Bar
-20°C / +200°C
O-ring Ø357 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
EPDM FDA USP VI
EPDM
-1/+25 Bar
-50°C / +150°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø357 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+25 Bar
-40°C / +140°C
O-ring Ø357 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+25 Bar
-60°C / +200°C
O-ring Ø357 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+25 Bar
-20°C / +200°C
O-ring Ø357 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+25 Bar
-60°C / +230°C
O-ring Ø357 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+25 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø357 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - ADI - Fri for phalater - DVDW
DIN ISO 7619-1
-1/+25 Bar
-20°C / +200°C
O-ring Ø407 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
EPDM FDA USP VI
EPDM
-1/+25 Bar
-50°C / +150°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø407 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+25 Bar
-40°C / +140°C
O-ring Ø407 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+25 Bar
-60°C / +200°C
O-ring Ø407 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+25 Bar
-20°C / +200°C
O-ring Ø407 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+25 Bar
-60°C / +230°C
O-ring Ø407 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+25 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø407 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - ADI - Fri for phalater - DVDW
DIN ISO 7619-1
-1/+25 Bar
-20°C / +200°C
O-ring Ø457 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
EPDM FDA USP VI
EPDM
-1/+16 Bar
-50°C / +150°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø457 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+16 Bar
-40°C / +140°C
O-ring Ø457 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+16 Bar
-60°C / +200°C
O-ring Ø457 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+16 Bar
-20°C / +200°C
O-ring Ø457 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+16 Bar
-60°C / +230°C
O-ring Ø457 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+16 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø457 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - ADI - Fri for phalater - DVDW
DIN ISO 7619-1
-1/+16 Bar
-20°C / +200°C
O-ring Ø507 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
EPDM FDA USP VI
EPDM
-1/+20 Bar
-50°C / +150°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø507 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+20 Bar
-40°C / +140°C
O-ring Ø507 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+20 Bar
-60°C / +200°C
O-ring Ø507 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+20 Bar
-20°C / +200°C
O-ring Ø507 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+20 Bar
-60°C / +230°C
O-ring Ø507 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+20 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø507 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - ADI - Fri for phalater - DVDW
DIN ISO 7619-1
-1/+20 Bar
-20°C / +200°C
O-ring Ø607 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
EPDM FDA USP VI
EPDM
-1/+16 Bar
-50°C / +150°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø607 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+16 Bar
-40°C / +140°C
O-ring Ø607 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+16 Bar
-60°C / +200°C
O-ring Ø607 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+16 Bar
-20°C / +200°C
O-ring Ø607 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+16 Bar
-60°C / +230°C
O-ring Ø607 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+16 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø607 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - ADI - Fri for phalater - DVDW
DIN ISO 7619-1
-1/+16 Bar
-20°C / +200°C
O-ring Ø707 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
Vulkaniceret EPDM FDA
EPDM
-1/+16 Bar
-40°C / +140°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø707 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+16 Bar
-40°C / +140°C
O-ring Ø707 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+16 Bar
-60°C / +200°C
O-ring Ø707 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+16 Bar
-20°C / +200°C
O-ring Ø707 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+16 Bar
-60°C / +230°C
O-ring Ø707 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+16 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø707 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - ADI - Fri for phalater - DVDW
DIN ISO 7619-1
-1/+16 Bar
-20°C / +200°C
O-ring Ø807 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
Vulkaniceret EPDM FDA
EPDM
-1/+12 Bar
-40°C / +140°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø807 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+12 Bar
-40°C / +140°C
O-ring Ø807 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+12 Bar
-60°C / +200°C
O-ring Ø807 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+12 Bar
-20°C / +200°C
O-ring Ø807 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+12 Bar
-60°C / +230°C
O-ring Ø807 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+12 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø807 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - ADI - Fri for phalater - DVDW
DIN ISO 7619-1
-1/+12 Bar
-20°C / +200°C
O-ring Ø907 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - KTW - NSF - ACS - DVGW - W-270 - WRAS - EN681-1
Vulkaniceret EPDM FDA
EPDM
-1/+10 Bar
-40°C / +140°C
10/8 x 10/5 mm
Certifikater.: DVGW - W-270
EPDM
-30°C / +90°C
O-ring Ø907 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af EPDM
FEP/EPDM ASTM D 2240
-1/+10 Bar
-40°C / +140°C
O-ring Ø907 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af Silikone
FEP/Silikone ASTM D 2240
-1/+10 Bar
-60°C / +200°C
O-ring Ø907 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - A3 - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude FEP Kerne af FKM(Viton)
FEP/FKM ASTM D 2240
-1/+10 Bar
-20°C / +200°C
O-ring Ø907 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI - Fri for phalater-/Kviksølv-/Malamine
O-ring Ude PFA Kerne af VMQ(Silikone)
PFA/VMQ ASTM D 2240
-1/+10 Bar
-60°C / +230°C
O-ring Ø907 x 8 mm
FDA 21 CFR 177.2600 - EU1935/2004 - USP VI - ADI
O-ring FDA USP
Silikone
-1/+10 bar
-50°C / +200°C
10/8 x 10/5 mm
FDA 21CFR 177.2600 - EU1935/2004 - USP VI - ADI - BfR XV
Silikone
-60°C / +200°C
O-ring Ø907 x 8 mm
FDA 21 CFR 177.2600 - A3 - Fri for phalater
FKM ASTM D 2240
-1/+10 Bar
-20°C / +200°C

Udvalgt variant

Vælg en variant på listen

Teknisk rådgivning

Jonna Jakobsen

Kundeservice
Har du har brug for hjælp? Kontakt os:
Har du brug for hjælp? Klik her!
Logo

COOKIE-INDSTILLINGER FOR OEMKLITSO.DK

Cookies hjælper os med at forbedre din oplevelse med os. Så for at kunne analysere trafikken, håndtere loginoplysninger, tilbyde dig personlige oplysninger og for at grundlæggende funktionalitet kan fungere på webssitet, skal vi bruge nogle cookies.

NØDVENDIGE COOKIES

Disse cookies er nødvendige for, at webstedet fungerer og kan ikke slås fra i vores systemer. De bruges normalt kun som reaktion på handlinger, du har foretaget i forbindelse med en serviceanmodning, f.eks. Når du angiver personlige præferencer, logger ind eller udfylder en formular.

ANALYSE OG MÅLING

Disse cookies giver os mulighed for at tælle antallet af besøg og trafikkilder, så vi kan måle og forbedre vores websteds ydeevne. De hjælper os med at vide, hvilke sider der er mere eller mindre populære, og hvordan besøgende navigerer rundt på webstedet. De oplysninger, som disse cookies indsamler, er aggregerede og derfor helt anonyme. Hvis du ikke tillader disse cookies, ved vi ikke, hvornår du har besøgt vores websted.

MARKEDSFØRING

Disse cookies kan tilføjes af vores partnere. De kan bruge dem til at oprette en profil af dig baseret på dine interesser for at vise dig mere relevante oplysninger. De gemmer ingen personlige oplysninger - kun oplysninger om din browser og enhed. Hvis du ikke accepterer disse cookies, får du en mere generel og mindre tilpasset brugeroplevelse.