Compact, High Purity, Spring loaded, Diaphram Sensor
TESCOM

Compact, High Purity, Spring loaded, Diaphram Sensor

12 serien High Purity trykreducerende regulator

  • Max indgangstryk: 10.3 bar
  • Udgangstryk: 0-2.1, 0-4.1, 0-6.9 bar
  • Leak: <1 x 10-9 atm cc/sec He
  • CV: 0.04, 0.08
  • Temperaturområde: -40 til 60 °C
Produktet har 1 varianter.
Køb Køb
Ultra High Purity,  Ultra High Flow, Spring loaded, Diaphram Sensor
TESCOM

Ultra High Purity, Ultra High Flow, Spring loaded, Diaphram Sensor

15 serien High Purity trykreducerende regulator

  • Facility Bulk Gas Delivery
  • CV: 8.0, 14.0
  • Temperatur: -29°C til 65°C
  • Connection: Tube
  • Ultra High Purity
Produktet har 1 varianter.
Køb Køb
Ultra high purity, Spring loaded, Diaphragm Sensor BA Grade 1/4" Point of use
TESCOM

Ultra high purity, Spring loaded, Diaphragm Sensor BA Grade 1/4" Point of use

22-2200 serien High Purity trykreducerende regulator

  • Max indgangstryk: 17.2 bar
  • Udgangstryk: 2.1, 4.1, 10.3 bar
  • Leak: 2 x 10-8 atm cc / sec PER ASTM E449
  • CV: 0.24
  • Temperaturområde: -40 til 60°C
Produktet har 1 varianter.
Køb Køb
Ultra high purity, Spring loaded, Diaphragm sensor, BA Grade 1/2" Point of use
TESCOM

Ultra high purity, Spring loaded, Diaphragm sensor, BA Grade 1/2" Point of use

22-5400 serien High Purity trykreducerende regulator

  • Max indgangstryk: 41.4 bar
  • Udgangstryk: 2.1, 4.1, 6.9, 10.3 bar
  • Leak: < 2 x 10-8 atm cc/sec He
  • CV: 1.0
  • Temperaturområde: -40 til 71°C
Produktet har 1 varianter.
Køb Køb
Ultra high purity, Spring loaded, Diaphragm Sensor, High flow, 1/2" Point of use
TESCOM

Ultra high purity, Spring loaded, Diaphragm Sensor, High flow, 1/2" Point of use

23 serien High Purity trykreducerende regulator

  • Max indgangstryk: 17.2 bar
  • Udgangstryk: 0-2.1, 0-4.1, 0-6.9 bar
  • Leak: <1 x 10-9 atm cc/sec He
  • CV: 1.8
  • Temperaturområde: -40 til 71°C
Produktet har 1 varianter.
Køb Køb
Ultra high purity, Spring loaded, Diaphragm sensor, High flow, Gas Cabinet (BSGS)
TESCOM

Ultra high purity, Spring loaded, Diaphragm sensor, High flow, Gas Cabinet (BSGS)

449-254 serien High Purity trykreducerende regulator

  • Max indgangstryk: 103 bar
  • Udgangstryk: 1.7 - 27.6 bar
  • Leak: <1 x 10-9 atm cc/sec
  • CV: 1.0
  • Temperaturområde: -40 til 60°C
Produktet har 1 varianter.
Køb Køb
Ultra high purity, Spring loaded, Diaphragm sensor, low flow 1/4" Point of use
TESCOM

Ultra high purity, Spring loaded, Diaphragm sensor, low flow 1/4" Point of use

64-2600 serien High Purity trykreducerende regulator

  • Max indgangstryk: 241 bar
  • Udgangstryk: 0-2.1, 0-4.1, 0-6.9, 0-10.3 og 17.2 bar
  • Leak: 1 x 10-9 atm cc/sec He
  • CV: 0.06, 0.15
  • Temperaturområde: -40 til 177°C
Produktet har 1 varianter.
Køb Køb
Ultra high purity, Spring loaded, Diaphragm sensor, low flow, 1/4" Point of use
TESCOM

Ultra high purity, Spring loaded, Diaphragm sensor, low flow, 1/4" Point of use

64-2800 serien High Purity trykreducerende regulator

  • Max indgangstryk: 241 bar
  • Udgangstryk: 2.1, 4.1, 6.9, 10.3 bar
  • Leak: Internal: Bubble-tight -External: 1 x 10-9 atm cc/sec He (ASTM test E499)
  • CV: 0.06, 0.15
  • Temperaturområde: -40 til 176°C
Produktet har 1 varianter.
Køb Køb
Ultra high purity, Spring loaded, Diaphragm Sensor, High flow, 1/2" Gas Cabinet (BSGS)
TESCOM

Ultra high purity, Spring loaded, Diaphragm Sensor, High flow, 1/2" Gas Cabinet (BSGS)

64-3200 serien High Purity trykreducerende regulator

  • Max indgangstryk: 103 bar
  • Udgangstryk: 2.1, 4.1, 6.9, 10.3, 13.8 bar
  • Leak: <1 x 10-9 atm cc/sec He
  • CV: 1.2
  • Temperaturområde: -40 til 177 °C
Produktet har 1 varianter.
Køb Køb
Ultra High Purity, Spring loaded, Diaphragm Sensor, Two Stage
TESCOM

Ultra High Purity, Spring loaded, Diaphragm Sensor, Two Stage

64-3400 serien High Purity trykreducerende regulator

  • Max indgangstryk: 241 bar
  • Udgangstryk: 2.1, 4.1, 6.9, 10.3 bar
  • Leak: Seat: < 4 x 10-9 atm cc/sec He - Diaphragm: < 1 x 10-9 atm cc/sec He
  • CV: 0.06, 0.15
  • Temperaturområde: -40 til 71 °C
Produktet har 1 varianter.
Køb Køb
Ultra High Purity, Spring loaded, Diaphragm Sensor, Low flow, 1/4" Gas Cabinet
TESCOM

Ultra High Purity, Spring loaded, Diaphragm Sensor, Low flow, 1/4" Gas Cabinet

64-3600 serien High Purity trykreducerende regulator

  • Max indgangstryk: 241 bar
  • Udgangstryk: 2.1, 4.1, 6.9, 10.3 bar
  • Leak: 1 x 10-9 atm cc/sec He
  • CV: 0.15, 0.06
  • Temperaturområde: -40 til 177 °C
Produktet har 1 varianter.
Køb Køb
Ultra High Purity, Spring loaded, Diaphragm Sensor, Sub-atmoferisk
TESCOM

Ultra High Purity, Spring loaded, Diaphragm Sensor, Sub-atmoferisk

64-5000 serien High Purity trykreducerende regulator

  • Max indgangstryk: 241 bar
  • Udgangstryk: 1.0, 2.1, 4.1, 6.9 bar
  • Leak: <1 x 10-9 atm cc/sec He
  • CV: 0.24, 0.15, 0.06
  • Temperaturområde: -40 til 71 °C
Produktet har 1 varianter.
Køb Køb
Ultra High Purity, Spring loaded, Diaphragm Sensor, High Flow, 1/2" Point of use
TESCOM

Ultra High Purity, Spring loaded, Diaphragm Sensor, High Flow, 1/2" Point of use

64-5400 serien High Purity trykreducerende regulator

  • Max indgangstryk: 41.4 bar
  • Udgangstryk: 2.1, 4.1, 6.9, 10.3
  • Leak: < 1 x 10-9 atm cc/sec He
  • CV: 1.0
  • Temperaturområde: -40 til 71 °C
Produktet har 1 varianter.
Køb Køb
Ultra High Purity, Spring loaded, Diaphragm Sensor, Low flow, 1/4" Point of use
TESCOM

Ultra High Purity, Spring loaded, Diaphragm Sensor, Low flow, 1/4" Point of use

74-2400 serien High Purity trykreducerende regulator

  • Max indgangstryk: 241 bar
  • Udgangstryk: 2.1, 4.1, 6.9 bar
  • Leak: 1 x 10-9 atm cc/sec He
  • CV: 0.06, 0.15
  • Temperaturområde: -40 til 177 °C
Produktet har 1 varianter.
Køb Køb
Ultra High Purity, Spring loaded, Diaphragm sensor, Medium flow, 1/2" Point of use
TESCOM

Ultra High Purity, Spring loaded, Diaphragm sensor, Medium flow, 1/2" Point of use

74-3000 serien High Purity trykreducerende regulator

  • Indgangstryk: 20.7, 41.4, 69, 241 bar
  • Udgangstryk: 1.0 bar, 0.21-2.1, 0.21-4.1, 0.28-6.9, og 0.28-10.3 bar
  • Leak: <1 x 10-9 atm cc/sec He per ASTM E449
  • CV: 0.5
  • Temperaturområde: -40 til 149 °C
Produktet har 1 varianter.
Køb Køb

Senseca opkober to virksomheder_front
Produktnyheder

Senseca styrker sin position med strategiske opkøb

Senseca styrker sin position med opkøbet af Biral og Geonica, der bringer ekspertise inden for miljømåling og sensorteknologi. Dette strategiske skridt kombinerer avanceret teknologi og bæredygtige løsninger til Smart City-udvikling, vedvarende energi og præcisionsmålinger.

Ajour messe 2024
Virksomhedsnyt

Mød os på Ajour

Vi glæder os til at deltage på Ajour-messen i Odense Congres Center den 28.-29. november. Hvis du er interesseret i at deltage en af dagene, så kan du kontakte os for en gratis billet.

Spild af trykluft
Tips og guides

Sådan undgår du spild af trykluft i pneumatiske systemer

Optimer jeres luftforbrug og reducer både energiforbrug og CO2-udledning med Emerson Aventics AF2 flowsensor. Denne intelligente sensor overvåger trykluftsflowet i realtid, opdager lækager og hjælper med at forbedre produktionsflowet. Med præcis dataindsamling gør den det nemt at træffe bedre beslutninger, reducere spild og sikre en mere bæredygtig drift.

Lær mere om magnetventiler
Tips og guides

Lær mere om magnetventiler

Ved dimensionering af magnetventiler er det vigtigt at overveje både fysiske og funktionsmæssige parametre, som rørdimensioner, medie, tryk, temperatur og flow. Her beskrives de forskellige funktionsparametre for at skabe en dybere forståelse af processen.

Definox ID App
Produktnyheder

Optimér vedligeholdelsen af dine ventiler

Definox AR-app gør ventilvedligeholdelse enkel ved hjælp af QR-koder, der giver adgang til logbøger, dokumenter og videovejledninger. Planlæg vedligeholdelse, øg produktiviteten, forbedr sikkerheden og reducer fejl med en intuitiv løsning, der hjælper dig trin for trin.

Vores Aarhusafdeling flytter
Virksomhedsnyt

Vores Århuskontor flytter til større lokaler

Vi glæder os til mere plads til os og fremtidige kollegaer på Agro Food Park 26

Teknisk rådgivning

Nicholas Haslund

Kundeservice
Har du har brug for hjælp? Kontakt os:
Har du brug for hjælp? Klik her!
Logo

COOKIE-INDSTILLINGER FOR OEMKLITSO.DK

Cookies hjælper os med at forbedre din oplevelse med os. Så for at kunne analysere trafikken, håndtere loginoplysninger, tilbyde dig personlige oplysninger og for at grundlæggende funktionalitet kan fungere på webssitet, skal vi bruge nogle cookies.

NØDVENDIGE COOKIES

Disse cookies er nødvendige for, at webstedet fungerer og kan ikke slås fra i vores systemer. De bruges normalt kun som reaktion på handlinger, du har foretaget i forbindelse med en serviceanmodning, f.eks. Når du angiver personlige præferencer, logger ind eller udfylder en formular.

ANALYSE OG MÅLING

Disse cookies giver os mulighed for at tælle antallet af besøg og trafikkilder, så vi kan måle og forbedre vores websteds ydeevne. De hjælper os med at vide, hvilke sider der er mere eller mindre populære, og hvordan besøgende navigerer rundt på webstedet. De oplysninger, som disse cookies indsamler, er aggregerede og derfor helt anonyme. Hvis du ikke tillader disse cookies, ved vi ikke, hvornår du har besøgt vores websted.

MARKEDSFØRING

Disse cookies kan tilføjes af vores partnere. De kan bruge dem til at oprette en profil af dig baseret på dine interesser for at vise dig mere relevante oplysninger. De gemmer ingen personlige oplysninger - kun oplysninger om din browser og enhed. Hvis du ikke accepterer disse cookies, får du en mere generel og mindre tilpasset brugeroplevelse.